Restek / Rxi

Rxi

####MAGENTO-BREADCRUMBS####

Rxi GC columns are highly inert, low bleed columns from Restek. They are made out of fused silica with various modifications.

####MAGENTO-PRODUCT-LINES####
####MAGENTO-CATEGORY-PRODUCTS####

Technical Data

Phase

Modification

USP

Tmax

Rxi-1ms

100%-Dimethylpolysiloxane

G1, G2, G38

330 °C

Rxi-1HT

100%-Dimethylpolysiloxane

N/A

400 °C

Rxi-5ms

5%-Phenyl-95%-dimethylpolysiloxane

G27, G36

330 °C

Rxi-5HT

5%-Phenyl-95%-dimethylpolysiloxane

N/A

400 °C

Rxi-XLB

proprietary

N/A

340 °C

Rxi-5Sil MS

5%-Phenyl-95%-dimethylpolysiloxane

N/A

320 °C

Rxi-35Sil MS

35%-Phenyl-65%-dimethylpolysiloxane

N/A

340 °C

Rxi-17

50%-Phenyl-50%-dimethylpolysiloxane

N/A

280 °C

Rxi-17Sil MS

50%-Phenyl-50%-dimethylpolysiloxane

G3

340 °C

Rxi-PAH

proprietary

N/A

360 °C

Rxi-624Sil MS

6%-Cyanopropylphenyl-94%-dimethylpolysiloxane

G43

300 °C

Rxi-1301-Sil MS

Cyano-phenyl-94%-dimethylpolysiloxane

N/A

320 °C

Rxi-SVOCms

proprietary 5%-phenyl

G27, G36

340 °C

Rxi-LAO

proprietary

N/A

300 °C

Rxi-1ms are non-polar general-purpose columns for a wide range of different applications.

Rxi-1HT are non-polar columns with a 40% longer lifetime due to a special designed fused silica tubing for high molecular weight hydrocarbons.

Rxi-5ms are low polar general-purpose columns for semi volatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, PCB congeners and solvent impurities.

Rxi-5HT are low-polar columns with a 40% longer lifetime due to a special designed fused silica tubing for high temperature applications such as mineral oil.

Rxi-XLB have a proprietary low polar phase for general-purpose applications such as pesticides, PCB congeners and PAHs.

Rxi-5Sil MS are low polar columns for general purpose applications.
 

Rxi-35Sil MS is a mid-polar phase with a special selectivity for substituted polar compounds such as drugs, pesticides, herbicides, PCBs, phenols, etc.
 

Rxi-17 are mid-polar columns for general purpose applications like pesticides, herbicides, rosin acids, phthalate esters, triglycerides and sterols.
 

Rxi-17Sil MS columns have a mid-polar phase for active environmental compounds such as PAHs.
 

Rxi-PAH have a mid-polar proprietary phase that is ideally suited for EFSA PAH4 analysis.
 

Rxi-624Sil MS are mid-polar, low-bleed and high-thermal stable columns for volatile organics and residual solvents and is a good choice for USP<467>.
 

Rxi-1301Sil MS are mid-polar phases with an stabilized cyano phase selectivity for terpenes, glycol ethers, fusel alcohols and other polar compounds.
 

Rxi-SVOCms is a proprietary phase with 5%-phenyl excellent performance for semivolatiles in complex matrices.
 

Rxi-LAO have a proprietary mid-polar phase especially designed for linear alpha olefin (LAO) impurity analysis.

Downloads

Brochures

####MAGENTO-CONTACT-SECTION####