Perkin-Elmer / Elite

Elite

####MAGENTO-BREADCRUMBS####

Elite is brand name for GC columns, manufactured by Perkin Elmer™. The columns cover a very wide range of polarity and application.

####MAGENTO-PRODUCT-LINES####
####MAGENTO-CATEGORY-PRODUCTS####

Technical Data

Elite-1:

  • Highly versatile general purpose column
  • Low bleed
  • Wide Applications range
     

Elite-1ms:

  • Engineered for extremely low bleed for MS detectors
     

Elite-1ht:

  • Designed for reduced bleed when operating at higher temperature (up to 380 °C)
     

Elite-5 / Elite-5 Amine / Elite-5ht:

  • General purpose column for a wide variety of applications
  • Commonly used for analysis of drugs, pesticides, hydrocarbons, PCBs, essential oils, semivolatiles and solvent impurities
  • Elite-5: Standard version stable up to 350 °C
  • Elite-5 Amine: Engineered for analysis of amines and other basic compounds
  • Elite-5ht: A high temperature version stable up to 400 °C
     

Elite-5ms:

  • Extremely Low Bleed and Inertness for MS applications
  • General purpose column ideal for GC/MS analysis of semivolatiles, PAHs, chlorinated hydrocarbons, phthalates, phenols, amines, organochlorine & organophosphorus pesticides, drugs and solvent impurities
     

Elite-5ms II:

  • The Elite-5ms II columns incorporate the same phase as the Elite-5 columns but are specifically tested for low bleed performance.
     

Elite-17:

  • General purpose columns for the analysis of pesticides, herbicides, phthalate esters, sterols, and rosin acids
     

Elite-17ms:

  • General purpose columns engineered for very low bleed to meet the requirements of sensitive MS detectors
     

Elite-17-ms+:

  • Säule für allgemeine Anwendungen
  • Die stationäre Phase besteht aus einer einzigartigen Mischung von verknüpften Dimethylpolysiloxanen und Diphenylsiloxanen mit einer besonderen Selektivität für aktive Umweltverbindungen, z.B. PAHs
  • Selektivität der gewöhnlichen Elite-17 Phase wird aufrechterhalten
  • Sehr geringes Bluten für massenspektroskopische Anwendungen
  • General purpose columns that are coated with a unique blend of linked dimethyl polysiloxanes and diphenyl polysiloxanes that is inert and selective for active environmental compounds, such as PAHs, while maintaining a similar selectivity and polarity as traditional Elite-17 phases
  • Engineered for extremely low bleed at higher temperature (up to 360 °C) as required for sensitive MS detectors.
     

Elite-35:

  • General purpose columns commonly used for organochlorine pesticides, PDB congeners (e.g. Alaclor mixes), herbicides, pharmaceuticals, sterols, phthalate esters and rosin acids
  • The Elite-35 column is a popular confirmation column for pesticides and herbicides, in conjunction with an Elite-5 or Elite-1701
     

Elite-35ms:

  • General purpose columns that are coated with a unique blend of linked dimethyl polysiloxanes and diphenyl polysiloxanes that are inert and selective for substituted polar compounds, such as drugs, pestcides, herbicides, PCBs and phenyls, while maintaining a similar selectivity and polarity as traditional Elite-35 phases
  • Engineered for extremely low bleed at higher temperature (up to 360 °C) as required for sensitive MS detectors.
     

Elite-200:

  • Unique selectivity for difficult separations
  • High stability, Inertness and low bleed - even for active compounds such as phenols, and with sensitive detectors such as ECDs, NPDs, and MSDs
  • Good general purpose column for solvents, Freon® fluorocarbons, alcohols, ketones, silanes, glycols,
  • and drugs of abuse
  • Excellent column for confirmation of phenols, nitrosamines, organochlorine pesticides, chlorinated hydrocarbons, and chlorophenoxy herbicides
     

Elite-225:

  • General purpose column for the analysis of FAMEs, carbohydrates, sterols and flavor compounds
  • Slightly less polar than bonded polyethylene glycol (PEG) phases
     

Elite-1301:

  • General purpose phase commonly used for the analysis of residual solvents, alcohols, oxygenates and volatile organic compounds
  • Suitable for MS and ECD detection
     

Elite-1701:

  • General purpose column for the analysis of alcohols, oxygenates, PCB congeners (e.g. Aroclor mixes), and pesticides
  • Suitable for MS and ECD detection
  • Ideal for confirmation analysis in combination with an Elite-35or Elite-5 column
     

Elite-WAX:

  • Polar general purpose PEG phase commonly used for the analysis of polar compounds like alkenols, glycols and aldehydes
     

Elite-WAX ETR:

  • Manufactured with a special bonding process that binds the Carbowax® polymer to the polar deactivated
  • silica - This results in a low bleed WAX column that exhibits extended lifetimes even when repeatedly heated to 260 °C
  • Usable for a wide range of compounds and matrices such as: FAMEs, flavor compounds, essential oils, solvents, aromatics, acrolein/acrylonitrile (EPA 603), oxygenated compounds, impurities in water matrices and alcoholic beverages
     

Elite-624:

  • Unique polarity analyzing volatile organic pollutants and it is recommended in U.S. EPA methods
  • Especially well-suited for EPA Method 524.2 since it resolves 2-Nitropropane from 1,1-Dichloropropanone, which share quantification ion m/z 43 and must be separated chromatographically
     

Elite-624ms:

  • Incorporates a unique proprietary blend of cyanopropyl and methyl siloxanes that results in a very inert, extremely low bleed and high thermal stability column 
  • Suitable for USP<467>
     

Elite-BAC 1 Advantage/ Elite-BAC 2 Advantage:

  • Application-specific columns for blood alcohol analysis
  • Baseline separate all critical compounds, including ethanol, methanol, acetone, tert-butanol, acetaldehyde, isopropanol, and n-propanol, in less than 2 minutes
  • High reproducibility
     

Elite-VMS:

  • For separating volatile organic compounds
  • Capable of separating the compounds listed in U.S. EPA Method 8260B in under 10 minutes
  • Suitable for GC/MS
     

Elite-XLB:

  • Proprietary low-polarity, very inert and exceptionally low bleed column for GC/MS analysis of pesticides, PCB congeners (e.g., Aroclor mixes) and PAHs.
  • Ideal for analyzing semivolatile compounds in drinking water (e.g., US EPA Method 525)
     

Elite-CLPesticides:

  • Designed for analysis of chlorinated pesticides
  • For US EPA methods 8081, 608 and CLP
     

Elite-502.2:

  • Analysis of volatiles by U.S. EPA method 502.2
     

Elite-608:

  • Analysis of semivolatile pesticides by U.S. EPA method 608
     

Elite-SimDist:

  • For simulated distillation
     

Elite-SimDist HT:

  • High temperature simulated distillation
     

Elite-MTBE:

  • Analysis of methyl tert-butylether and other oxgenates
     

Elite-TPH:

  • Analysis of total petroleum hydrocarbons
     

Elite-2560:

  • Application-specific column for the analysis of cis/trans isomers of fatty acid methyl esters (FAMEs)
     

Elite-PONA:

  • Detailed analysis of petroleum naphtha
     

Elite-FFAP:

  • For the analysis of free fatty acids
     

Elite-23:

  • Analysis of cis/trans isomers in fatty acid methyl esters (FAMEs) and dioxins
Column name

Phase

Polarity

USP

Diameter

Film thickness

Tmax[1]

Elite-1

Dimethyl polysiloxane (100%)

Non-Polar

G1,
G2,
G38

0.05 mm


0.10 mm


0.18 mm


0.20 mm


0.25 mm


0.32 mm


0.45 mm


0.53 mm

0.05, 0.20 µm


0.10, 0.40 µm


0.18, 0.40 µm


0.33 µm


0.10, 0.25, 0.50, 1.0 µm


0.10, 0.25, 0.50, 1.0, 1.5, 3.0, 5.0 µm


0.13, 0.42, 1.27, 2.55, 4.25 µm


0.15, 0.50, 1.5, 3.0, 5.0 µm

260-350 °C

Elite-1ms

Dimethyl polysiloxane (100%)

Non-Polar

N/A

0.18 mm


0.25 mm


0.32 mm

0.18, 2.0 µm


0.25, 0.50, 1.0 µm


0.25, 0.50, 1.0, 4.0 µm

330-350 °C

Elite-1ht

Dimethyl polysiloxane (100%)

Non-Polar

N/A

0.25 mm


0.32 mm

0.10 µm


0.10 µm

400 °C

Elite-5

Diphenyl-/dimethylpolysiloxane
(5%/95%)

Non-Polar

G27,
G36

0.05 mm


0.10 mm


0.18 mm


0.20 mm


0.25 mm


0.32 mm


0.45 mm


0.53 mm

0.05, 0.20 µm


0.10, 0.40 µm


0.18, 0.40 µm


0.33 µm


0.10, 0.25, 1.0 µm


0.10, 0.25, 1.0 µm


0.13, 0.42, 1.27, 4.25 µm


0.50, 1.5, 5.0 µm

260-360 °C

Elite-5ms

N/A

Non-Polar

G27,
G36

0.18 mm


0.20 mm


0.25 mm


0.32 mm


0.53 mm

0.18 µm


0.33 µm


0.25, 0.50, 1.0 µm


0.25, 0.50, 0.52, 1.0 µm


1.5 µm

310-350 °C

Elite-5ms II

Diphenyl-/dimethylpolysiloxane
(5%/95%)

Non-Polar

G27,
G36

0.25 mm


0.32 mm

0.10, 0.25, 0.50, 1.0 µm


0.10, 0.25, 0.50, 1.0 µm

325-350 °C

Elite-5 Amines

Diphenyl-/dimethylpolysiloxane
(5%/95%)

Non-Polar

G27,
G36

0.25 mm


0.32 mm


0.53 mm

0.50, 1.0 µm


1.0, 1.5 µm


1.0, 3.0 µm

280-315 °C

Elite-5ht

Diphenyl-/dimethylpolysiloxane
(5%/95%)

Non-Polar

G27,
G36

0.25 mm


0.32 mm

0.10 µm


0.10 µm

400 °C

Elite-17

(50%-phenyl)-methylpolysiloxane

Mid-Polar

G3

0.05 mm


0.10 mm


0.18 mm


0.25 mm


0.32 mm


0.45 mm


0.53 mm

0.05, 0.10 µm


0.02, 0.10, 0.20 µm


0.18, 0.30 µm


0.15, 0.25, 0.50 µm


0.15, 0.25, 0.50 µm


0.85, 1.7 µm


1.0, 2.0 µm

250-330 °C

Elite-17ht

(50%-phenyl)-methylpolysiloxane

Mid-Polar

G3

0.25 mm


0.32 mm

0.15 µm


0.15 µm

300-320 °C

Elite-17ms

Diphenyl-/dimethylpolysiloxane
(50%/50%)

Mid-Polar

G3

0.18 mm


0.25 mm


0.32 mm

0 18 µm


0.15, 0.25 µm


0.15, 0.25 µm

300-320 °C

Elite-17ms+

Proprietary

Mid-Polar

G3

0.15 mm


0.18 mm


0.25 mm


0.32 mm

0.15 µm


0.18, 0.36 µm


0.25 µm


0.25 µm

340-360 °C

Elite-35

Diphenyl-/dimethylpolysiloxane
(35%/65%)

Mid-Polar

G42

0.25 mm


0.32 mm


0.45 mm


0.53 mm

0.15, 0.25 µm


0.25, 0.50 µm


0.42, 0.85 µm


0.50, 1.0 µm

260-320 °C

Elite-35ms

Proprietary

Mid-Polar

G42

0.25 mm


0.32 mm

0.25, 0.50, 1.0 µm


0.25, 0.50, 1.0 µm

320-360 °C

Elite-200

(Trifluoropropyl)-methylpolysiloxane

Mid-polar

G6

0.25 mm


0.32 mm


0.53 mm

0.10, 0.25, 0.50, 1.0 µm


0.25, 0.50, 1.0, 1.5 µm


0.25, 0.50, 1.0, 1.5, 3.0 µm

260-340 °C

Elite-225

Cyanopropylmethyl-
/phenylmethylpolysiloxane (50%/50%)

polar

G7,
G19

0.05 mm


0.10 mm


0.18 mm


0.25 mm


0.32 mm


0.45 mm


0.53 mm

0.05 µm


0.10 µm


0.2 µm


0.15, 0.25 µm


0.15, 0.25 µm


0.85 µm


1.0 µm

200-240 °C

Elite-1301

Cyanopropyl-phenyl-
/dimethylpolysiloxane (6%/94%)

Mid-Polar

G43

0.18 mm


0.25 mm


0.32 mm


0.45 mm


0.53 mm

0.40 µm


0.25, 1.0 µm


0.25, 1.0 µm


0.85 µm


1.0 µm

260-280 °C

Elite-1701

(14%-Cyanopropylphenyl)-
methylpolysiloxane

Mid-Polar

G46

0.25 mm


0.32 mm


0.45 mm


0.53 mm

0.15, 0.25, 1.0 µm


0.15, 0.25, 1.0 µm


0.42, 0.85 µm


0.50, 1.0 µm

250-280 °C

Elite-Wax

Polyethylene Glycol (PEG)

Polar

N/A

0.25 mm


0.32 mm


0.45 mm


0.53 mm

0.15, 0.25, 0.50 µm


0.15, 0.25, 0.50 µm


0.42, 0.85, 1.7 µm


0.50, 1.0 µm

230-250 °C

Elite MWax

Polyethylene Glycol (PEG)

Polar

N/A

0.53 mm

1.0 µm

240-250 °C

Elite-Wax ETR

Polyethylene Glycol (PEG)

Polar

N/A

0.25 mm


0.32 mm


0.45 mm


0.53 mm

0.25, 0.50 µm


0.25, 0.50, 1.0 µm


0.85, 1.7 µm


1.0, 2.0 µm

220-250 °C

Elite-624

Cyanopropyl-phenyl-
/dimethylpolysiloxane (6%/94%)

Mid-polar

G43

0.18 mm


0.20 mm


0.25 mm


0.32 mm


0.45 mm


0.53 mm

1.0 µm


1.12 µm


1.4 µm


1.8 µm


2.55 µm


3.0 µm

240 °C

Elite-624ms

Blend of Cyanopropyl
and Methylsiloxanes

Mid-Polar

G43

0.18 mm


0.25 mm


0.32 mm

1.0 µm


1.4 µm


1.8 µm

320 °C

Elite-BAC 1 Advantage

N/A

N/A

N/A

0.18 mm


0.32 mm


0.53 mm

1.0 µm


1.8 µm


3.0 µm

240-260 °C

Elite-BAC 2 Advantage

N/A

N/A

N/A

0.18 mm


0.32 mm


0.53 mm

0.34 µm


0.60 µm


1.0 µm

240-260 °C

Elite-BAC 3 Advantage

N/A

N/A

N/A

0.18 mm

0.30 µm

250 °C

Elite VMS

N/A

N/A

N/A

0.18 mm


0.25 mm


0.32 mm


0.45 mm


0.53 mm

1.0 µm


1.4 µm


1.8 µm


2.55 µm


3.0 µm

240-260 °C

Elite-XLB

Proprietary

Low-Polar

N/A

0.18 mm


0.20 mm


0.25 mm


0.32 mm


0.53 mm

0.18 µm


0.33 µm


0.10, 0.25, 1.0 µm


0.10, 0.25, 0.50, 1.0 µm


1.5 µm

320-360 °C

Elite Volatiles

Proprietary

N/A

N/A

0.25 mm


0.32 mm


0.45 mm

1.4 µm


1.8 µm


2.55 µm

240 °C

Elite-CLPesticides

N/A

N/A

N/A

0.25 mm


0.32 mm


0.53 mm

0.25 µm


0.50 µm


0.50 µm

300-340 °C

Elite-CLPesticides 2

N/A

N/A

N/A

0.25 mm


0.32 mm


0.53 mm

0.20 µm


0.25 µm


0.42 µm

240-260 °C

Elite-502.2

Proprietary Dimethyl-
diphenyl polysiloxane

Low-Polar

N/A

0.25 mm


0.45 mm


0.53 mm

1.4 µm


2.55 µm


3.0 µm

250-270 °C

Elite-608

Phenyl-methylpolysiloxane

Mid-Polar

N/A

0.25 mm


0.45 mm


0.53 mm

0.50 µm


0.42, 0.70 µm


0.50, 0.83 µm

260-310 °C

Elite-SimDist

Specially processed
Dimethylpolysiloxane

Non-Polar

N/A

0.45 mm


0.53 mm

2.55 µm


3.0 µm

360 °C

Elite-SimDist HT

100% Dimethylpolysiloxane

Non-Polar

N/A

0.53 mm

0.15 µm

400 °C

Elite-MTBE

Proprietary

Low-Polar

N/A

0.45 mm


0.53 mm

2.55 µm


3.0 µm

250 °C

Elite-TPH

Diphenyl-/dimethylpolysiloxane
(5%/95%)

Low-Polar

N/A

0.32 mm


0.45 mm

0.25 µm


1.0 µm

290-320 °C

Elite-2560

Biscyanopropylpolysiloxane

Polar

N/A

0.25 mm

0.20 µm

N/A

Elite-PONA

Specially processed
Dimethylpolysiloxane

Non-Polar

N/A

0.20 mm


0.25 mm

0.50 µm


0.50 µm

300-320 °C

Elite-FFAP

Nitroterephthalic acid
modified PEG (bonded)

Polar

N/A

0.25 mm


0.32 mm


0.45 mm


0.53 mm

0.25 µm


0.25 µm


0.85 µm


1.0 µm

240-250 °C

Elite-23

(5%-cyanopropylphenyl)-
biscyanopropylpolysiloxane

N/A

N/A

0.25 mm

0.15, 0.25 µm

N/A

[1 ] Depending on the film thickness and whether work is carried out at a constant temperature or with a gradient

Downloads

Brochures

####MAGENTO-CONTACT-SECTION####