MicroSolv / Cogent

Cogent

####MAGENTO-BREADCRUMBS####

Cogent HPLC Column™ from the US manufacturer Microsolv™ Tech. Corp. based on the unique silica hydride technology. The stationary phase is formed from a high purity Type B silica backbone, which is modified to cover the silica surface with silicon-hydride (Si-H) bonds, thus replacing >95% of surface silanols (Si-OH). As a result, Cogent Type-C™ particles have only a weakly associated water shell. Using patented technology, various bonded phases are produced from the unique silica hydride surface with direct silicon-carbon bonds. These extremely strong non-polar bonds offer increased stability over traditional silica based phases.

Cogent HPLC columns™ can be used in three different modes of HPLC: (1.) Classic reversed-phase (RP), (2.) Normal-phase with non-polar solvents, such as hexane, and (3.) Normal-phase with aqueous eluents (ANP). Further advantages of these phases are fast equilibration between gradient runs, unique retention and selectivity properties, and excellent suitability for LC-MS.

####MAGENTO-PRODUCT-LINES####
####MAGENTO-CATEGORY-PRODUCTS####

Technical Data

Phase-Name

Modification

Particle Size

Pore Size

End-capping

C-Content

USP

Surface

pH-Range

Tmax

Cogent Bidentate C18™

C18

4 µm

100 Å

-

18−19%

L1

390 m2/g

2.0−10.0

80 °C

Cogent Bidentate C18 2.ō™

C18

2.2 µm

120 Å

-

20%

 

340 m2/g

2.0−10.0

80 °C

Cogent Bidentate C8™

C8

4 µm

100 Å

-

13−14%

 

390 m2/g

2.0−8.0

80 °C

Cogent Bidentate C8 2.ō™

C8

2.2 µm

120 Å

-

11−12%

 

340 m2/g

2.0−8.0

80 °C

Cogent Bidentate C8 300™

C8

5 µm

300 Å

-

5%

 

100 m2/g

2.0−7.5

80 °C

Cogent Phenyl Hydride™

Phenyl

4 µm

100 Å

-

10−12%

 

390 m2/g

2.0−8.0

80 °C

Cogent Phenyl Hydride 2.ō™

Phenyl

2.2 µm

120 Å

-

9−10%

 

340 m2/g

2.0−8.0

80 °C

Cogent Diol™

Diol

4 µm

100 Å

-

9−10%

 

390 m2/g

2.0−8.0

80 °C

Cogent Diol 2.ō™

Diol

2.2 µm

120 Å

-

9−10%

 

340 m2/g

2.0−8.0

80 °C

Cogent Amide™

Amide

4 µm

100 Å

-

2−3%

 

390 m2/g

2.0−7.5

80 °C

Cogent Hydride™

N/A

4 µm

100 Å

-

2%

 

390 m2/g

2.0−7.5

80 °C

Cogent Hydride 2.ō™

N/A

2.2 µm

120 Å

-

2%

 

340 m2/g

2.0−7.5

80 °C

Cogent UDC-Cholesterol™

Cholesterol

4 µm

100 Å

-

13−14%

 

390 m2/g

2.0−8.0

80 °C

Cogent UDC-Cholesterol 2.ō™

Cholesterol

2.2 µm

120 Å

-

13−14%

 

340 m2/g

2.0−8.0

80 °C

Cogent UDA™

Undecanoic Acid

4 µm

100 Å

-

14−15%

 

390 m2/g

2.0−8.0

80 °C

Cogent UDA 2.ō™

Undecanoic Acid

2.2 µm

120 Å

-

14−15%

 

340 m2/g

2.0−8.0

80 °C

Cogent Silica-C™

-

4 µm

100 Å

-

0%

 

390 m2/g

2.0−7.0

60 °C

Cogent Silica-C 2.ō™

-

2.2 µm

120 Å

-

0%

 

340 m2/g

2.0−7.0

60 °C

Downloads

Brochures