Restek™ MXT® GC columns are metal capillary columns for gas chromatography. The columns cover a wide range of applications and are thermally very stable.
Column name | Phase | Polarity | USP | Diameter | Film thickness | Tmax[1] |
MXT®-1 | Dimethyl polysiloxane (100%) | Non-Polar | G1, | 0.18 mm
| 0.20, 0.40 µm
| 250-430 °C |
MXT®-1 SimDist | Dimethyl polysiloxane (100%) | Non-Polar | N/A | 0.53 mm | 0.15 µm | 400-430 °C |
MXT®-1HT SimDist | Dimethyl polysiloxane (100%) | Non-Polar | N/A | 0.53 mm | 0.10, 0.20, 0.21, 0.88, 1.0, 1.2, 2.65, 5.0 µm | 360-450 °C |
MXT®-5 | Diphenyl- | Low-polar | G27, | 0.18 mm
| 0.20, 0.40 µm
| 270-430 °C |
MXT®-20 | 1,4-bis-(dimethylsiloxy) | Mid-polar | N/A | 0.25 mm | 0.25 µm | 300-340 °C |
MXT®-35 | Diphenyl- | Mid-polar | G42 | 0.25 mm
| 0.50 µm
| 240-340 °C |
MXT®-50 | Methyl-phenylpolysiloxane (100%) | Mid-Polar | G3 | 0.53 mm | 0.83, 1.0, 1.5 µm | 250-300 °C |
MXT®-65 | Diphenyl- | Polar | N/A | 0.25 mm | 0.25 µm | 300 °C |
MXT®-65TG | Diphenyl- | Polar | N/A | 0.25 mm
| 0.10 µm
| 370 °C |
MXT®-200 | Trifluoropropyl- | Mid-Polar | G6 | 0.25 mm
| 0.50, 1.0 µm
| 260-400 °C |
MXT®-500 SimDist | N/A | Non-Polar | N/A | 0.53 mm | 0.15 µm | 420-430 °C |
MXT®-502.2 | Proprietary Diphenyl- | N/A | N/A | 0.28 mm
| 1.6 µm
| 250-320 °C |
MXT®-624 | Cyanopropylmethyl-phenylmethyl-dimethylpolysiloxane | Mid-Polar | N/A | 0.18 mm
| 1.0 µm
| 240-280 °C |
MXT®-1301 | Cyanopropylphenyl- | Mid-polar | G43 | 0.25 mm
| 0.25 µm
| 240-280 °C |
MXT®-1701 | Cyanopropylmethyl- | Mid-polar | N/A | 0.25 mm
| 0.25, 1.0 µm
| 250-280 °C |
MXT®-2887 | Dimethyl polysiloxane (100%) | Non-Polar | N/A | 0.53 mm | 2.65 µm | 360-400 °C |
MXT®-WAX | Polyethylene Glycols (PEG) | Polar | G14, | 0.25 mm
| 0.25, 0.50 µm
| 220-260 °C |
MXT®-Biodiesel TG | Proprietary | N/A | N/A | 0.32 mm
| 0.10 µm
| 380-430 °C |
MXT®-Volatiles | Proprietary Diphenyl/ | N/A | N/A | 0.25 mm
| 1.0 µm
| 250-320 °C |
MXT®-Alumina BOND/MAPD | alumina | N/A | N/A | 0.53 mm | 10 µm | 250 °C |
MXT®-Alumina BOND/Na2SO4 -deactivated column | alumina | N/A | N/A | 0.53 mm | 10 µm | 200 °C |
MXT® Msieve 5A | 5Å Molecular sieve | N/A | N/A | 0.25 mm
| 20 µm
| 300 °C |
MXT® Q-Bond | N/A | N/A | N/A | 0.25 mm
| 8 µm
| 280-300 °C |
MXT® S-Bond | N/A | N/A | N/A | 0.53 mm | 20 µm | 250 °C |
[1 ] Depending on the film thickness and whether a constant temperature or a gradient is used
MXT®-1:
MXT®-1 SimDist:
MXT®-1HT SimDist:
MXT®-5:
MXT®-20:
MXT®-35:
MXT®-50:
MXT®-65:
MXT®-65TG:
MXT®-200:
MXT®-500 SimDist:
MXT®-502.2:
MXT®-624:
MXT®-1301:
MXT®-1701:
MXT®-2887:
MXT®-WAX:
MXT®-Biodiesel TG:
MXT®-Volatiles:
MXT®-Alumina BOND/MAPD (PLOT column):
MXT®-Alumina BOND/Na2SO4 (PLOT column):
MXT® Msieve 5A (PLOT column):
MXT® Q-Bond (PLOT column):
MXT® S-Bond (PLOT column):